Chinese researchers improve nuclear-clock readout and stability


Measurements explain how improved detection steadies the Tsinghua-led clock, while showing why frequency stability is not the same as absolute accuracy.
The Chinese team reports an approximately twentyfold improvement in its nuclear clock’s absorption signal-to-noise ratio, calculated for one second, and corresponding gains in frequency stability in a study published in Nature on 7 October. The prototype is one of two independently built working nuclear clocks that lock ultraviolet lasers to an energy transition inside thorium-229 nuclei, as Physics World reported that day.
One team is led by Ekkehard Peik at Germany’s Physikalisch-Technische Bundesanstalt (PTB) and Thorsten Schumm at Austria’s TU Wien. That collaboration had previously demonstrated laser excitation of the thorium-229 transition and embedded thorium-229 in calcium-fluoride crystals. The other team is led by Shiqian Ding at Tsinghua University, with collaborators at 13 other Chinese institutions.
Atomic clocks use transitions between electron energy levels as their frequency reference. Nuclear clocks instead use a transition within an atom’s nucleus, as Nature’s accompanying commentary explains. Thorium-229, a particular form of thorium, is unusual: its nuclear transition can be reached directly with current laser technology.
Both teams put thorium-229 into millimetre-sized calcium-fluoride crystals and illuminated them with continuous-wave ultraviolet lasers, which emit steadily rather than in pulses. The lasers have narrow linewidths, meaning their light covers only a small range of frequencies. Measuring absorption through the crystals and correcting the laser frequency produces a stabilized reference that the teams can compare continuously with standards derived from atomic clocks.
The Chinese study explains why the readout matters. The excited nuclear state lasts about ten minutes, making measurements of the light emitted afterward slow. Instead, the researchers monitor ultraviolet light passing through the crystal. This absorption measurement gives a rapid indication of whether the laser is exciting the nuclear transition.
The absorption is weak: at resonance, the nuclei absorb roughly 0.01% of the ultraviolet light. The researchers repeatedly vary the laser frequency and extract the corresponding change in transmitted light. Near the chosen transition, that signal indicates how far the laser frequency is from the target. A feedback loop uses the signal to correct the frequency for the next measurement cycle. The nucleus therefore steers the laser, rather than merely being measured by it.
An external optical reference still keeps the Chinese laser steady between nuclear measurements. The nuclear feedback supplies the corrections that hold it to the transition.
The PTB–TU Wien collaboration incorporated more thorium-229 into its crystals, while the Tsinghua-led team generated higher laser power. Physics World reports that both approaches tend to strengthen the signal relative to background noise and improve stability. Scarce access to thorium-229 led the Chinese team to develop a crystal-growing method requiring only 1.4 micrograms of the isotope.
Fractional frequency instability describes fluctuations in a clock’s frequency relative to the frequency itself; lower values mean a steadier output. It is not absolute accuracy, which concerns how close the output is to the correct reference frequency. In the tables, τ is the averaging time, expressed in seconds by τ/s.
| Team | Distinguishing approach | Fractional frequency instability |
|---|---|---|
| PTB–TU Wien | More thorium-229 in the crystals | 3 × 10⁻¹² / √(τ/s) |
| Tsinghua-led team | Higher laser power | 5 × 10⁻¹³ / √(τ/s) |
Physics World also reported that the Chinese team’s transition-frequency measurements in two independently fabricated crystals agreed with each other and with earlier ultraviolet frequency-comb measurements at JILA in the US. That provides a check that separately made crystals can yield consistent frequencies.
The Chinese team first replaced its photomultiplier detector with a phototube that could handle more ultraviolet light without saturating. It then replaced its initial S1 crystal with a clearer TS1 crystal that transmitted more light and had stronger nuclear absorption. Together, these changes improved the one-second absorption signal-to-noise ratio by approximately twentyfold compared with the initial S1-and-photomultiplier setup. That made the laser’s frequency offset easier to measure precisely.
| Configuration | Fractional frequency instability |
|---|---|
| S1 crystal and photomultiplier | 1 × 10⁻¹¹ / √(τ/s) |
| S1 crystal and phototube | 6 × 10⁻¹² / √(τ/s) |
| TS1 crystal and phototube | 2 × 10⁻¹² / √(τ/s) |
| Optimized TS1 crystal and phototube | 5 × 10⁻¹³ / √(τ/s) |
The final optimization increased the transmitted ultraviolet power, raised the proportion of time spent measuring to about 85% and reduced unwanted changes in light intensity. Over the measured interval, the instability was statistically consistent with decreasing as the inverse square root of averaging time. That describes the observed fluctuations, not a guarantee of the clock’s absolute accuracy.
These are in-loop measurements: the researchers calculated instability from the frequency record inside the feedback system. They argue that this faithfully estimates the operating clock’s instability because the external optical reference was independently measured to be substantially steadier at comparable averaging times.
The PTB–TU Wien collaboration used its clock to search for possible interactions involving ultralight scalar dark matter, a proposed form of the invisible matter in the Universe. By constraining fluctuations and drifts in the nuclear transition energy, the team set limits on interactions with photons—the particles of light—and with the strong nuclear force. Physics World describes those limits as comparable to those from today’s best atomic clocks. This was not a detection of dark matter, and the comparison concerns interaction limits, not overall clock accuracy.
A major remaining obstacle is the nuclear resonance’s linewidth—the range of frequencies across its response. Peik told Physics World that his team observed roughly 30 kilohertz, or 30,000 hertz, whereas the natural linewidth should be far below 1 hertz. He says a narrower response would allow more stable operation. His team is working to increase laser power, improve detector signals relative to noise and understand how thorium’s position within the crystal affects the observed width.
Ding identifies better host crystals than calcium fluoride as an important next step that could narrow the transition and improve both stability and accuracy. He also wants to develop a clock using trapped thorium ions—electrically charged atoms—which would be more isolated from their surroundings. Ding says that route is technically much harder but could ultimately offer the highest accuracy.
Observations and atmospheric modelling point to a possible way for rapid cooling above Arsia Mons to turn water vapour directly into ice particles.
3 min

A warming-adjusted weekly index exceeds December 2015 levels in a series starting in 2008, while forecasters expect El Niño to peak in December.
4 min

Imported fuel and rising electricity costs complicate the choice between oil heating, heat pumps and changes to the energy supply.
3 min